Data Loggers

Why Choose AEMC® Instruments Data Loggers?

  • AEMC® Instruments data loggers are versatile, powerful and cost-effective.
  • We offer single, dual, four, and eight channel data loggers to address a wide range of applications, both for general and special-purposes such as temperature, humidity, voltage, thermocouple, and events.
  • Simple to use, operation in a few minutes
  • Includes software for analyzing and reporting the recorded data
  • Models available with remote access via the internet

Cost Effective & Quick Ship

Our data loggers are built with exceptional quality for a great value and we offer a fast delivery of one week (in-stock).

Key Features (model specific)

  • Programmable storage modes and rates
  • Accurate representation of measured signals for AC models
  • Stores over 240,000 measurements ensuring no valuable data is missed with more than 8 hours at 8 samples per second
  • Easily installed anywhere quickly – operational in seconds
  • Compact and runs on alkaline batteries
  • Wireless (Bluetooth) or USB communication
  • Comprehensive DataView graphing, analysis and report generation software
  • Display and analyze real-time data on your PC
  • and more...

AEMC Dataloggers Measure a Wide Variety of Applications

  • Assists electricians and engineers in finding problems that occur randomly in fault/intermittent current detection
  • Neutral current monitoring finds unwanted leakage currents
  • Harmonic real-time current monitoring
  • Load profiling which size loads for proper transformer and meter selection
  • Process loops monitoring – finds troubled sensors and controls
  • HVAC and general temperature
  • and more...

Compatible Current Probes and Accessories

There are many compatible current probes available as accessories for select models.

Tech Support

AEMC provides complete technical support through our technical hot line 800-945-2362 (ext.351). Speak directly to one of our tech support team members or e-mail your questions to our tech team techsupport@aemc.com

Data Loggers

  • Data Logger Model DL913

    Cat. #2153.613-channel AC current data logger with three integral 24-inch flexible current sensors, measurement ranges of up to 300 and 3000 Amps, and data storage rates of 8 per second.

  • Data Logger Model DL914

    Cat. #2153.624-channel AC current data logger with four integral 24-inch flexible current sensors, measurement ranges of up to 300 and 3000 Amps, and data storage rates of 8 per second.

  • Simple Logger® II Model L261

    Cat. #2126.05
    1-Channel, TRMS, 600VAC/DC, DataView® Software
    One channel recording device that performs line tracking by taking 64 samples over one line cycle. Harmonic measurements are calculated from these 64 samples. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency 50 or 60Hz. Records TRMS at a rate of up to eight times per second. TRMS calculations are performed on a single line cycle. Features easy and intuitive setup from a computer using DataView software.

  • Simple Logger® II Model L562

    Cat. #2126.35
    2-Channel, TRMS, Voltage & Current, DataView® Software
    Two channel voltage/current data logger. Features include Extended Recording Mode (XRM®) and delayed start time. Records TRMS at a rate of up to eight times per second. TRMS calculations are performed on a single line cycle. Includes easy and intuitive setup from a computer using DataView® software.

  • Data Logger Model L452

    Cat. #2153.51
    Data Logger Model L452 (2-Channel, w/LCD, 100mV/1V/10VDC, 4 to 20mADC, Event & Pulse, DataView® Software
    Two channel data logger for recording DC voltage, DC current, pulses and events. Connect to various sensors to measure pressure, temperature, flow, humidity and many other types of values. Also records events such as machine run time. Communicates via USB or Bluetooth for configuration and data transfer. Setup from a computer via free DataView software, or via the front-panel interface.

  • Simple Logger® Model SL10

    Cat. #2156.10
    Simple Logger® Model SL10 (Voltage, 100mVDC)

  • Simple Logger® Model SL11

    Cat. #2156.11
    Simple Logger® Model SL11 (Voltage, 1VDC)

  • Simple Logger® Model SL12

    Cat. #2156.12
    Simple Logger® Model SL12 (Voltage, 10VDC)

  • Simple Logger® Model SL13

    Cat. #2156.13
    Simple Logger® Model SL13 (Voltage, 50VDC)

  • Simple Logger® Model SL20

    Cat. #2156.20
    Simple Logger® Model SL20 (Current, 4 to 20mADC)

  • Simple Logger® Model SL50

    Cat. #2156.50
    Simple Logger® Model SL50 (Temperature, Thermocouple)

Show Discontinued Products

DISCOVER THE CHAUVIN® ARNOUX GROUP

  • Chauvin Arnoux logo and website link
  • Chauvin Arnoux Energy logo and website link
  • Chauvin Arnoux Pyro Control logo and website link
  • Chauvin Arnoux Manumesure logo and website link
  • Chauvin Arnoux AMRA logo and website link
  • Chauvin Arnoux Spectralys logo and website link
  • Chauvin Arnoux Indatech logo and website link
  • Metrix logo and website link
  • Multimetrix logo and website link